SimSci Esscor SCP270 (Simulated Control Processor 270) software from Invensys, included in its Dynamic Simulation Suite (DSS), is replacing FSIM Plus. It provides Foxboro I/A Series system users with a comprehensive environment for modeling, testing, and system checkout prior to start up. SCP270 is delivered as part of a turnkey OTS from Invensys or for users for DCS Control Checkout for control logic checkout. Use of SCP270 will dramatically reduce start-up and commissioning times. The reduced start-up times provide customers with significant cost savings. This new software also allows for efficient operator training, control systems validation, and enhanced plant performance.
Showing posts with label FSIM Plus. Show all posts
Showing posts with label FSIM Plus. Show all posts
Wednesday, 16 October 2013
Saturday, 14 September 2013
Question on SCP270 - Differences with FSIM Plus
Posted on 10:49 by Unknown
There was a question in the DYNSIM LinkedIn group that I though we should post on the blog:
"Apart from the new name, could you summarize what is new compared to FSIM Plus "
Here is the response from Janet Parker, the product manager for SCP270:
SCP270, which is simulation for the current Foxboro Control Processor, provides Foxboro I/A Series system users with a comprehensive environment for modeling, testing, and system checkout prior to start up. It replaces the legacy FSIM Plus product, that was based on the discontinued AW Integrator technology, with a modern infrastructure that behaves identically to the CP270 with the same control block algorithms and communication systems. This means that peer-to-peer sizing and communication, memory footprint, and block count are identical between the SCP and a real CP. This one-to-one CP-to-SCP instancing differs from FSIM Plus that where several real CPs install in a single ‘super’ FSIM CP. A single SCP host computer can run up to 40 SCP instances, many times more than an FSIM Station, reducing the overall hardware footprint. Unlike FSIM Plus, the SCP host computer is not dependent on the I/A Series infrastructure, but runs on a modern, off-the-shelf Windows 7 64-bit or Server 2008 R2 OS multi-core enabled system. Unlike FSIM Plus, SCP270 v1 is not tied to a single, specific version of I/A Series software. It works with I/A Series 8.5 – 8.8 and will work with the next version of I/A Series software. Unlike FSIM Plus, SCP270 supports virtualization. For users who do not need I/O tieback or Operator Training Simulator (OTS) capabilities, the SCP270 software can run independently of DYNSIM, just like a real CP, so that I/A Series users do not need to learn how to use another modeling package. When used independently of DYNSIM, SCP software can be mixed with real CPs before or during a DCS Factory Acceptance Test which allows Foxboro to ship the actual hardware early. Finally, installing the SCP software is extremely easy. Unlike FSIM Plus, there is no need to create a custom System Definition to include a special station type. The I/A Series infrastructure ‘sees’ an SCP270 just as if it were a real CP270.
"Apart from the new name, could you summarize what is new compared to FSIM Plus "
Here is the response from Janet Parker, the product manager for SCP270:
SCP270, which is simulation for the current Foxboro Control Processor, provides Foxboro I/A Series system users with a comprehensive environment for modeling, testing, and system checkout prior to start up. It replaces the legacy FSIM Plus product, that was based on the discontinued AW Integrator technology, with a modern infrastructure that behaves identically to the CP270 with the same control block algorithms and communication systems. This means that peer-to-peer sizing and communication, memory footprint, and block count are identical between the SCP and a real CP. This one-to-one CP-to-SCP instancing differs from FSIM Plus that where several real CPs install in a single ‘super’ FSIM CP. A single SCP host computer can run up to 40 SCP instances, many times more than an FSIM Station, reducing the overall hardware footprint. Unlike FSIM Plus, the SCP host computer is not dependent on the I/A Series infrastructure, but runs on a modern, off-the-shelf Windows 7 64-bit or Server 2008 R2 OS multi-core enabled system. Unlike FSIM Plus, SCP270 v1 is not tied to a single, specific version of I/A Series software. It works with I/A Series 8.5 – 8.8 and will work with the next version of I/A Series software. Unlike FSIM Plus, SCP270 supports virtualization. For users who do not need I/O tieback or Operator Training Simulator (OTS) capabilities, the SCP270 software can run independently of DYNSIM, just like a real CP, so that I/A Series users do not need to learn how to use another modeling package. When used independently of DYNSIM, SCP software can be mixed with real CPs before or during a DCS Factory Acceptance Test which allows Foxboro to ship the actual hardware early. Finally, installing the SCP software is extremely easy. Unlike FSIM Plus, there is no need to create a custom System Definition to include a special station type. The I/A Series infrastructure ‘sees’ an SCP270 just as if it were a real CP270.
Wednesday, 11 September 2013
SCP270 replaces FSIM Plus
Posted on 11:37 by Unknown
SimSci Esscor SCP270 (Simulated Control Processor 270) software from Invensys, included in its Dynamic Simulation Suite (DSS), is replacing FSIM Plus. It provides Foxboro I/A Series system users with a comprehensive environment for modeling, testing, and system checkout prior to start up. SCP270 is delivered as part of a turnkey OTS from Invensys or for users for DCS Control Checkout for control logic checkout. Use of SCP270 will dramatically reduce start-up and commissioning times. The reduced start-up times provide customers with significant cost savings. This new software also allows for efficient operator training, control systems validation, and enhanced plant performance.
For more information on SCP270, please go to the website.
Monday, 25 March 2013
Current SimSci-Esscor Software Versions
Posted on 06:50 by Unknown
I figured it would be valuable to provide you with the most up-to-date versions of our software
The product names are hyper linked to their product websites so that you can get more information if needed.
The product names are hyper linked to their product websites so that you can get more information if needed.
Design Software PRO/II 9.1 with patch 3 VISUAL FLOW 5.5 INPLANT 4.2 HEXTRAN 9.2 DATACON 3.2 PIPEPHASE 9.5 with patch 1 | OTS Software DYNSIM 5.0 TRISIM Plus 2.2 FSIM Plus 4.7.1 | Optimization Software: ROMeo 6.0 with patch 2 Connoisseur 15.0 with patch 2 |
Patches can be downloaded from the “Software Updates & Knowledge Base” site. Full versions can be downloaded from the “Electronic Software Distribution” site. | ||
Posted in ARPM, DATACON, DYNSIM, FSIM Plus, HEXTRAN, INPLANT, MBM, PIPEPHASE, PRO/II, ROMeo, TRISIM Plus, VISUAL FLOW
|
No comments
Tuesday, 8 January 2013
Coming soon, SimSci-Esscor’s Foxboro Simulation of CP270 or SCP270 will replace FSIM Plus
Posted on 21:00 by Unknown
Coming soon, SimSci-Esscor’s Foxboro Simulation of CP270 or SCP270 will replace FSIM Plus. The modern and flexible infrastructure is architected to fit seamlessly into I/A Series and Foxboro Control Software (FCS). It is extremely easy to install, configure and run. Functionally, it replaces the I/A Series CP270 and associated FBM hardware for use in off-line validation and for Operator Training Simulators. It connects to the I/A Series HMI and configurator (IEE/ICC/IACC) through the MESH network and resides on a generic Intel-based 64-bit OS. DYNSIM can be optionally co-located or connected through a separate network. It will function with I/A Series 8.5 – 8.8 and DYNSIM 5.1.